What to do, blows out a gas boiler

Most often, people living in private homes have a problem that will be discussed in the article. Naturally, it is necessary to fight it. But first you need to understand the sources of the appearance of the defect.

Why blows a gas boiler in the wind

What to do if the gas boiler blows in the wind? Wind can get in through the duct and extinguish the burner. But this is not a reason to panic. It is necessary to identify the cause, first make a diagnosis: what will be discussed in the written article.

REFERENCE! The most unpleasant thing that can happen is a decrease in the room temperature or a malfunction in the operability of the device.

Blowing out the boiler for other reasons.

It is clear what to do if the boiler blows through the pipe with wind. But there are many other options for the origin of the problem. Let's consider each of them in more detail:

  1. Ice on the tip. During frosts in winter, it may be that the ice crust covers the ventilation outlet in the heater. And, of course, such a formation creates an obstacle to air circulation. Due to the cessation of air mass access, the boiler will certainly die out.
  2. Low gas pressure or poor quality. This is mainly due to a malfunction of the whole system. However, there are other reasons. For example, if uncharacteristic sounds or noises are made, this means that the gas meter is not functioning properly. Therefore, the required fuel flow is not allowed. To verify this, it is recommended to check the status of the entire mechanism. In addition, there may be a breakdown of the sensor, which monitors temperature and leakage. Thanks to the triggering of the gas analyzers, the boiler can also be extinguished. Another reason may be the waste of gas, leading to a significant decrease in pressure. As a result, the impermeability of the compounds is gradually destroyed.
  3. Burning pipe. Of course, when the quality of the product is damaged, an undesirable hole arises. Using it, air enters the system, which significantly worsens the process of the entire device.

How to solve the problem with the chimney

What to do if the boiler blows out through the chimney? The method of solution will depend on the type of malfunction.

  1. To avoid icing, you will have to clean the entire structure, and then deal with the insulation of the chimney pipe.
  2. If you feel a characteristic odor, it is worth diluting a soap solution. And with it and a sponge to wipe all possible connections. In the case of blistering after the procedure, you must immediately call a special team, as this means that there is a leak. This usually happens with minimal gas pressure.
  3. When holes form in the pipe, it should be replaced. An old and burnt product will not be suitable for further action.

Special Deflector: Fix a Problem

In addition to the above methods, there is another universal method. It is recommended to install a special unit - a deflector, which prevents the mass of wind from getting into the hole. Its principle of operation is quite simple: air is dispersed when it is sent to the pipe. Thus, the wind power decreases.

Therefore, if you blow the boiler, you will need a regular cone, which will bring excellent results. You can also purchase a special ring. Thanks to him, the air stream breaks, after which a vortex is created and its strength is lost. Accordingly, there is no back pressure, that is, the gas burns out.

There are a lot of similar devices in stock on the market, but they require an individual approach. Therefore, despite all the ease of use, it is better to contact the seller-manufacturer in order to make a reasonable choice.

ATTENTION! It is important to remember that the instructions often prescribe the places in which the device should be installed. Usually these are zones on the leeward side of the structure.

Reverse traction

What to do if the boiler blows out in strong winds? Another way is to create your own design "gap traction". It is characterized as a special zone, with the help of which the passage of air masses along the reverse path is prevented, that is, an obstacle appears. This is somewhat similar to the previous version, however, the device has the shape of a truncated cone.

Its owner must install in the place of the rupture of the chimney. Its narrow end is directed by the movement of hot air. The advantage of this design is the isolation of the flow, due to which its power is significantly reduced.

Before installing the device, consult a specialist to avoid adverse effects.

Drawing conclusions, we can say that not every serviceability can be solved independently. In some situations, it is best to contact professionals who can accurately diagnose the problem and provide assistance. Otherwise, if the appliance is not used correctly, you will have to buy new equipment.